Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Beaulieu this is corporate & commercial work on midwall split systems, attended within about 80 minutes of dispatch.We work across every major brand installed in Beaulieu, and diagnostics start from the plated design data rather than a guess.Compressor swaps are done with a full system flush, new drier and an oil-charge check so the replacement is not killed by the original contamination.Equestrian estate access with resident authorisation. Aircon Repairs & Servicing bookings in Beaulieu are logged against Block 16 so we can allow for power availability on site.

Typical response window
80 minutes from Midrand & Waterfall Corridor
Distance from Sandton CBD
21.3 km
Municipal water hardness
hard (205 ppm)
Load-shedding schedule
Block 16
Access & compliance
Equestrian estate access with resident authorisation.
Typical installed systems
Smallholding-style estate homes with multiple standalone systems.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Is a compressor replacement guaranteed?

Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.

Do you work inside gated estates?

Regularly. Technician details, ID numbers and vehicle registration are submitted to the HOA or gatehouse before the appointment so access is cleared in advance.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.