Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Inanda this is sandton prime work on midwall split systems, attended within about 45 minutes of dispatch.We work across every major brand installed in Inanda, and diagnostics start from the plated design data rather than a guess.Every visit starts with a full diagnostic and a written quote before any part is fitted.Equestrian estate character; access via gated roads with visitor logging. Aircon Repairs & Servicing bookings in Inanda are logged against Block 4 so we can allow for power availability on site.
- Typical response window
- 45 minutes from Sandton
- Distance from Sandton CBD
- 2.4 km
- Municipal water hardness
- soft (110 ppm)
- Load-shedding schedule
- Block 4
- Access & compliance
- Equestrian estate character; access via gated roads with visitor logging.
- Typical installed systems
- Very large stands, ducted zoned HVAC and cellar cooling common.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Why is my ice cloudy or melting too fast?
Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.
Is scale really a problem for ice machines here?
Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.