Samsung Midwall Split Servicing — Gas Leak Detection & Refill in Benmore Centre

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Benmore Centre this is sandton prime work on midwall split systems, attended within about 40 minutes of dispatch.

On Samsung equipment specifically — wind-free splits, dvm s vrf and side-by-side refrigeration — the faults we see most in Benmore Centre are ice build-up on evaporator in french-door fridges and indoor display board comms loss.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Centre management booking for roof and plant access. Aircon Repairs & Servicing bookings in Benmore Centre are logged against Block 4 so we can allow for power availability on site.

Typical response window
40 minutes from Sandton
Distance from Sandton CBD
1.9 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 4
Access & compliance
Centre management booking for roof and plant access.
Typical installed systems
Retail refrigeration and packaged rooftop HVAC.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

What does an E1 or E4 error mean on a Samsung aircon in Benmore Centre?

E1 is a room temperature sensor error and E4 is an evaporator sensor error. Both are usually a failed thermistor or a connector that has corroded on the indoor board, and both are inexpensive parts once the correct one is identified.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.