Midwall Split Servicing — Annual Service Contract in Benmore Centre

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Benmore Centre this is sandton prime work on midwall split systems, attended within about 40 minutes of dispatch.

We work across every major brand installed in Benmore Centre, and diagnostics start from the plated design data rather than a guess.

Fixed-fee annual cover with scheduled visits, priority response and reporting suitable for HOA and facilities managers.

Centre management booking for roof and plant access. Aircon Repairs & Servicing bookings in Benmore Centre are logged against Block 4 so we can allow for power availability on site.

Typical response window
40 minutes from Sandton
Distance from Sandton CBD
1.9 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 4
Access & compliance
Centre management booking for roof and plant access.
Typical installed systems
Retail refrigeration and packaged rooftop HVAC.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

What does an annual service contract include?

Scheduled visits, priority response between visits, a written condition report per unit and fixed labour rates for the contract year.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.