Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Sunninghill this is luxury gated estates work on midwall split systems, attended within about 55 minutes of dispatch.We work across every major brand installed in Sunninghill, and diagnostics start from the plated design data rather than a guess.Cloudy, soft or hollow cubes point at water quality, a low water level in the sump, a partially scaled evaporator, or a machine running short cycles. We test water hardness and TDS on site, then correct the freeze cycle time so cubes come out clear and at full weight.Office park and residential mix; complexes need body corporate clearance. Aircon Repairs & Servicing bookings in Sunninghill are logged against Block 11 so we can allow for power availability on site.

Typical response window
55 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
9.6 km
Municipal water hardness
moderate (165 ppm)
Load-shedding schedule
Block 11
Access & compliance
Office park and residential mix; complexes need body corporate clearance.
Typical installed systems
Townhouses and offices with midwall splits and light commercial HVAC.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.

How fast can you get to me?

Emergency callouts are dispatched to the next available technician, with the arrival window confirmed by SMS when the vehicle leaves.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.