Aircon Re-Gassing & Leak Repair — Thermostat & Controller Replacement in Sunninghill
Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Sunninghill this is luxury gated estates work on all split types systems, attended within about 55 minutes of dispatch.
We work across every major brand installed in Sunninghill, and diagnostics start from the plated design data rather than a guess.
Faulty or obsolete thermostats and wall controllers replaced with compatible units and re-commissioned.
Office park and residential mix; complexes need body corporate clearance. Aircon Repairs & Servicing bookings in Sunninghill are logged against Block 11 so we can allow for power availability on site.
- Typical response window
- 55 minutes from Fourways & Northern Suburbs
- Distance from Sandton CBD
- 9.6 km
- Municipal water hardness
- moderate (165 ppm)
- Load-shedding schedule
- Block 11
- Access & compliance
- Office park and residential mix; complexes need body corporate clearance.
- Typical installed systems
- Townhouses and offices with midwall splits and light commercial HVAC.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
How often should an aircon need re-gassing?
A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
How fast can you get to me?
Emergency callouts are dispatched to the next available technician, with the arrival window confirmed by SMS when the vehicle leaves.
Do you top up gas without finding the leak?
No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.
Related jobs nearby
- Inverter Aircon Repair in Sunninghill
- Midea Inverter Aircon Repair
- Sirair Inverter Aircon Repair
- Carrier Inverter Aircon Repair
- Inverter Aircon Repair — Preventative Service
- Inverter Aircon Repair — Annual Service Contract
- Inverter Aircon Repair — Thermostat & Controller Replacement
- Midwall Split Servicing in Sunninghill
- Midea Midwall Split Servicing
- Sirair Midwall Split Servicing
- Carrier Midwall Split Servicing
- Midwall Split Servicing — no ice being produced
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.