VRV / VRF System Maintenance — Gas Leak Detection & Refill in Design Quarter
Planned maintenance and fault finding on multi-storey VRV/VRF systems and their branch selector boxes. In Design Quarter this is luxury gated estates work on vrv / vrf systems, attended within about 60 minutes of dispatch.
We work across every major brand installed in Design Quarter, and diagnostics start from the plated design data rather than a guess.
Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.
Tenant and centre coordination for shared plant. Aircon Repairs & Servicing bookings in Design Quarter are logged against Block 12 so we can allow for power availability on site.
- Typical response window
- 60 minutes from Fourways & Northern Suburbs
- Distance from Sandton CBD
- 13 km
- Municipal water hardness
- hard (185 ppm)
- Load-shedding schedule
- Block 12
- Access & compliance
- Tenant and centre coordination for shared plant.
- Typical installed systems
- Restaurant and showroom cooling.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
Common questions
Do you top up gas without finding the leak?
No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.
Can you work after trading hours?
Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.
Is a compressor replacement guaranteed?
Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Related jobs nearby
- Inverter Aircon Repair in Design Quarter
- Carrier Inverter Aircon Repair
- York Inverter Aircon Repair
- Dunham-Bush Inverter Aircon Repair
- Inverter Aircon Repair — slow or stalled harvest cycle
- Inverter Aircon Repair — scale build-up and descaling
- Inverter Aircon Repair — water leaking from the machine
- Midwall Split Servicing in Design Quarter
- Alliance Midwall Split Servicing
- Midea Midwall Split Servicing
- Sirair Midwall Split Servicing
- Midwall Split Servicing — Thermostat & Controller Replacement
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.