Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Broadacres this is luxury gated estates work on midwall split systems, attended within about 70 minutes of dispatch.We work across every major brand installed in Broadacres, and diagnostics start from the plated design data rather than a guess.Every visit starts with a full diagnostic and a written quote before any part is fitted.Estate and complex access with pre-booking. Aircon Repairs & Servicing bookings in Broadacres are logged against Block 13 so we can allow for power availability on site.
- Typical response window
- 70 minutes from Fourways & Northern Suburbs
- Distance from Sandton CBD
- 16.2 km
- Municipal water hardness
- hard (195 ppm)
- Load-shedding schedule
- Block 13
- Access & compliance
- Estate and complex access with pre-booking.
- Typical installed systems
- Estate homes with ducted plant.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Is a compressor replacement guaranteed?
Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Why is my ice cloudy or melting too fast?
Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.