Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Broadacres this is luxury gated estates work on midwall split systems, attended within about 70 minutes of dispatch.On Alliance equipment specifically — locally supported inverter splits, ducted units and heat pumps — the faults we see most in Broadacres are sensor drift causing short-cycling and capacitor failure on non-inverter units.Every visit starts with a full diagnostic and a written quote before any part is fitted.Estate and complex access with pre-booking. Aircon Repairs & Servicing bookings in Broadacres are logged against Block 13 so we can allow for power availability on site.

Typical response window
70 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
16.2 km
Municipal water hardness
hard (195 ppm)
Load-shedding schedule
Block 13
Access & compliance
Estate and complex access with pre-booking.
Typical installed systems
Estate homes with ducted plant.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Do you stock Alliance parts in Broadacres?

Yes. Alliance is locally supported, so boards, sensors, capacitors and fan motors are available quickly, which keeps repair times short.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.