Fixed-schedule maintenance contracts with priority breakdown response, filter changes and hygiene records for venues that cannot trade without ice. In Midrand this is corporate & commercial work on planned maintenance systems, attended within about 70 minutes of dispatch.We work across every major brand installed in Midrand, and diagnostics start from the plated design data rather than a guess.Every visit starts with a full diagnostic and a written quote before any part is fitted.Mixed residential and industrial access. Ice Machine Repairs bookings in Midrand are logged against Block 15 so we can allow for power availability on site.
- Typical response window
- 70 minutes from Midrand & Waterfall Corridor
- Distance from Sandton CBD
- 16.8 km
- Municipal water hardness
- hard (190 ppm)
- Load-shedding schedule
- Block 15
- Access & compliance
- Mixed residential and industrial access.
- Typical installed systems
- Complexes plus light industrial refrigeration.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R134a | HFC (A1) | 80-140 kPa at -5 degrees C evaporating | 900-1 200 kPa at 45 degrees C ambient | Wine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps. |
| R404A | HFC blend (near-azeotropic) | 40-60 kPa (approx. 2-4 bar) | 1500-1900 kPa | Older commercial ice machines, cube makers, ice bins and blast chillers |
| R448A | HFO/HFC blend (low GWP) | 50-75 kPa | 1600-2000 kPa | Modern commercial ice machines, cube and flake units, coldroom retrofits |
Common questions
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Is a compressor replacement guaranteed?
Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Why is my ice cloudy or melting too fast?
Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.