LG Undercounter ice maker repair in Dunkeld

Undercounter and back-bar ice maker repair for built-in units in kitchens, entertainment areas and wine rooms, including door seal, drain and hydrocarbon-charge work. In Dunkeld this is sandton prime work on built-in undercounter ice makers systems, attended within about 50 minutes of dispatch.

On LG equipment specifically — dual inverter splits, multi v vrf and instaview refrigeration — the faults we see most in Dunkeld are blocked drain causing indoor water leaks and linear compressor failure on refrigerators.

Every visit starts with a full diagnostic and a written quote before any part is fitted.

Heritage overlays on some streets restrict visible external plant. Ice Machine Repairs bookings in Dunkeld are logged against Block 6 so we can allow for power availability on site.

Typical response window
50 minutes from Sandton
Distance from Sandton CBD
4.6 km
Municipal water hardness
moderate (130 ppm)
Load-shedding schedule
Block 6
Access & compliance
Heritage overlays on some streets restrict visible external plant.
Typical installed systems
Older character homes retrofitted with concealed multi-split systems.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.
R290 (propane)Natural hydrocarbon (A3 flammable)30-50 kPa1000-1400 kPaUndercounter and self-contained ice makers, nugget machines, back-bar units

Common questions

Is an LG linear compressor worth repairing in Dunkeld?

On refrigerators still within their ten-year sealed system warranty, yes. Outside it, we quote the compressor and drier replacement against the value of the unit so you can decide on the numbers rather than a guess.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.