LG Harvest cycle and thermostat fault repair — no ice being produced in Dunkeld

Repair of harvest-cycle faults: hot-gas solenoids, harvest thermostats and probes, curtain switches and controller boards that leave ice stuck on the plate. In Dunkeld this is sandton prime work on controls and harvest circuit systems, attended within about 50 minutes of dispatch.

On LG equipment specifically — dual inverter splits, multi v vrf and instaview refrigeration — the faults we see most in Dunkeld are blocked drain causing indoor water leaks and linear compressor failure on refrigerators.

When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.

Heritage overlays on some streets restrict visible external plant. Ice Machine Repairs bookings in Dunkeld are logged against Block 6 so we can allow for power availability on site.

Typical response window
50 minutes from Sandton
Distance from Sandton CBD
4.6 km
Municipal water hardness
moderate (130 ppm)
Load-shedding schedule
Block 6
Access & compliance
Heritage overlays on some streets restrict visible external plant.
Typical installed systems
Older character homes retrofitted with concealed multi-split systems.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R404AHFC blend (near-azeotropic)40-60 kPa (approx. 2-4 bar)1500-1900 kPaOlder commercial ice machines, cube makers, ice bins and blast chillers
R448AHFO/HFC blend (low GWP)50-75 kPa1600-2000 kPaModern commercial ice machines, cube and flake units, coldroom retrofits

Common questions

Is an LG linear compressor worth repairing in Dunkeld?

On refrigerators still within their ten-year sealed system warranty, yes. Outside it, we quote the compressor and drier replacement against the value of the unit so you can decide on the numbers rather than a guess.

My machine is full of ice but drops nothing, what is wrong?

That is a harvest failure. The plate is frozen, but the hot-gas solenoid, harvest probe or curtain switch is not completing the release cycle. We test each component and time a full harvest before signing the machine off.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.