Ice machine evaporator plate replacement — Gas Leak Detection & Refill in Dunkeld
Evaporator plate replacement where scale pitting, refrigerant leaks or physical damage stop a plate from releasing ice cleanly. In Dunkeld this is sandton prime work on evaporator assembly systems, attended within about 50 minutes of dispatch.
We work across every major brand installed in Dunkeld, and diagnostics start from the plated design data rather than a guess.
Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.
Heritage overlays on some streets restrict visible external plant. Ice Machine Repairs bookings in Dunkeld are logged against Block 6 so we can allow for power availability on site.
- Typical response window
- 50 minutes from Sandton
- Distance from Sandton CBD
- 4.6 km
- Municipal water hardness
- moderate (130 ppm)
- Load-shedding schedule
- Block 6
- Access & compliance
- Heritage overlays on some streets restrict visible external plant.
- Typical installed systems
- Older character homes retrofitted with concealed multi-split systems.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R134a | HFC (A1) | 80-140 kPa at -5 degrees C evaporating | 900-1 200 kPa at 45 degrees C ambient | Wine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps. |
| R404A | HFC blend (near-azeotropic) | 40-60 kPa (approx. 2-4 bar) | 1500-1900 kPa | Older commercial ice machines, cube makers, ice bins and blast chillers |
| R448A | HFO/HFC blend (low GWP) | 50-75 kPa | 1600-2000 kPa | Modern commercial ice machines, cube and flake units, coldroom retrofits |
Common questions
Do you top up gas without finding the leak?
No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Is scale really a problem for ice machines here?
Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.
There is water on the floor under my ice machine, can you find the leak?
We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.
Related jobs nearby
- Cube ice machine repair in Dunkeld
- LG Cube ice machine repair
- Carrier Cube ice machine repair
- Sub-Zero Cube ice machine repair
- Cube ice machine repair — Gas Leak Detection & Refill
- Cube ice machine repair — Compressor Replacement
- Cube ice machine repair — Error Code Diagnosis & Repair
- Flake ice machine repair in Dunkeld
- Sub-Zero Flake ice machine repair
- KIC Flake ice machine repair
- Defy Flake ice machine repair
- Flake ice machine repair — Thermostat & Controller Replacement
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.