Samsung Ice machine evaporator plate replacement — no ice being produced in Atholl Square

Evaporator plate replacement where scale pitting, refrigerant leaks or physical damage stop a plate from releasing ice cleanly. In Atholl Square this is sandton prime work on evaporator assembly systems, attended within about 40 minutes of dispatch.

On Samsung equipment specifically — wind-free splits, dvm s vrf and side-by-side refrigeration — the faults we see most in Atholl Square are digital inverter compressor start failure and ice build-up on evaporator in french-door fridges.

When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.

Tenant coordination for shared plant. Ice Machine Repairs bookings in Atholl Square are logged against Block 4 so we can allow for power availability on site.

Typical response window
40 minutes from Sandton
Distance from Sandton CBD
3.1 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 4
Access & compliance
Tenant coordination for shared plant.
Typical installed systems
Restaurant and deli refrigeration with split HVAC.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.
R404AHFC blend (near-azeotropic)40-60 kPa (approx. 2-4 bar)1500-1900 kPaOlder commercial ice machines, cube makers, ice bins and blast chillers
R448AHFO/HFC blend (low GWP)50-75 kPa1600-2000 kPaModern commercial ice machines, cube and flake units, coldroom retrofits

Common questions

What does an E1 or E4 error mean on a Samsung aircon in Atholl Square?

E1 is a room temperature sensor error and E4 is an evaporator sensor error. Both are usually a failed thermistor or a connector that has corroded on the indoor board, and both are inexpensive parts once the correct one is identified.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.