Brema Ice machine evaporator plate replacement in Atholl Square
Evaporator plate replacement where scale pitting, refrigerant leaks or physical damage stop a plate from releasing ice cleanly. In Atholl Square this is sandton prime work on evaporator assembly systems, attended within about 40 minutes of dispatch.
On Brema equipment specifically — granular and cube ice makers widely fitted in bars and cafes — the faults we see most in Atholl Square are thermostat out of calibration and spray bar blockage.
Every visit starts with a full diagnostic and a written quote before any part is fitted.
Tenant coordination for shared plant. Ice Machine Repairs bookings in Atholl Square are logged against Block 4 so we can allow for power availability on site.
- Typical response window
- 40 minutes from Sandton
- Distance from Sandton CBD
- 3.1 km
- Municipal water hardness
- moderate (140 ppm)
- Load-shedding schedule
- Block 4
- Access & compliance
- Tenant coordination for shared plant.
- Typical installed systems
- Restaurant and deli refrigeration with split HVAC.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R134a | HFC (A1) | 80-140 kPa at -5 degrees C evaporating | 900-1 200 kPa at 45 degrees C ambient | Wine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps. |
| R404A | HFC blend (near-azeotropic) | 40-60 kPa (approx. 2-4 bar) | 1500-1900 kPa | Older commercial ice machines, cube makers, ice bins and blast chillers |
| R448A | HFO/HFC blend (low GWP) | 50-75 kPa | 1600-2000 kPa | Modern commercial ice machines, cube and flake units, coldroom retrofits |
Common questions
Why does my Brema ice maker show a no-water alarm
The sump is not filling: inlet filter, solenoid or float. On this water supply a scaled spray bar and pump impeller are the usual companions to that alarm.
Can you work after trading hours?
Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.
How urgent is a slow harvest cycle?
Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.
How fast can you get to me?
Emergency callouts are dispatched to the next available technician, with the arrival window confirmed by SMS when the vehicle leaves.
Related jobs nearby
- Cube ice machine repair in Atholl Square
- Carrier Cube ice machine repair
- Sub-Zero Cube ice machine repair
- KIC Cube ice machine repair
- Cube ice machine repair — Not Cooling Diagnosis
- Cube ice machine repair — Water Leak Repair
- Cube ice machine repair — no ice being produced
- Flake ice machine repair in Atholl Square
- Samsung Flake ice machine repair
- LG Flake ice machine repair
- Carrier Flake ice machine repair
- Flake ice machine repair — Error Code Diagnosis & Repair
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.