New ice machine installation sized to actual daily demand, with correct water treatment, drainage, ventilation and commissioning documentation. In Fourways Mall Precinct this is luxury gated estates work on new installations systems, attended within about 60 minutes of dispatch.We work across every major brand installed in Fourways Mall Precinct, and diagnostics start from the plated design data rather than a guess.Every visit starts with a full diagnostic and a written quote before any part is fitted.Centre management contractor booking and night work windows. Ice Machine Repairs bookings in Fourways Mall Precinct are logged against Block 12 so we can allow for power availability on site.
- Typical response window
- 60 minutes from Fourways & Northern Suburbs
- Distance from Sandton CBD
- 12.7 km
- Municipal water hardness
- hard (185 ppm)
- Load-shedding schedule
- Block 12
- Access & compliance
- Centre management contractor booking and night work windows.
- Typical installed systems
- Retail display refrigeration and packaged HVAC.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R134a | HFC (A1) | 80-140 kPa at -5 degrees C evaporating | 900-1 200 kPa at 45 degrees C ambient | Wine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps. |
| R448A | HFO/HFC blend (low GWP) | 50-75 kPa | 1600-2000 kPa | Modern commercial ice machines, cube and flake units, coldroom retrofits |
| R290 (propane) | Natural hydrocarbon (A3 flammable) | 30-50 kPa | 1000-1400 kPa | Undercounter and self-contained ice makers, nugget machines, back-bar units |
Common questions
What size ice machine do I need?
Size on peak daily draw, not average: roughly 0.5 to 1 kg of ice per restaurant cover per day, more for cocktail bars and function venues. We calculate demand on site, then specify machine output plus bin storage and the water treatment your supply needs.
Can you work after trading hours?
Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.
There is water on the floor under my ice machine, can you find the leak?
We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.
How urgent is a slow harvest cycle?
Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.