Ice machine re-gassing with proper leak detection first: we find and fix the leak, then weigh in a fresh charge rather than topping up. In Broadacres this is luxury gated estates work on sealed refrigeration system systems, attended within about 70 minutes of dispatch.On Brema equipment specifically — granular and cube ice makers widely fitted in bars and cafes — the faults we see most in Broadacres are pump impeller scaling and drain pump failure.Every visit starts with a full diagnostic and a written quote before any part is fitted.Estate and complex access with pre-booking. Ice Machine Repairs bookings in Broadacres are logged against Block 13 so we can allow for power availability on site.

Typical response window
70 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
16.2 km
Municipal water hardness
hard (195 ppm)
Load-shedding schedule
Block 13
Access & compliance
Estate and complex access with pre-booking.
Typical installed systems
Estate homes with ducted plant.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.
R404AHFC blend (near-azeotropic)40-60 kPa (approx. 2-4 bar)1500-1900 kPaOlder commercial ice machines, cube makers, ice bins and blast chillers
R448AHFO/HFC blend (low GWP)50-75 kPa1600-2000 kPaModern commercial ice machines, cube and flake units, coldroom retrofits
R290 (propane)Natural hydrocarbon (A3 flammable)30-50 kPa1000-1400 kPaUndercounter and self-contained ice makers, nugget machines, back-bar units

Common questions

Why does my Brema ice maker show a no-water alarm

The sump is not filling: inlet filter, solenoid or float. On this water supply a scaled spray bar and pump impeller are the usual companions to that alarm.

Can you just top up the gas in my ice machine?

No: a machine low on refrigerant has a leak, and topping up hides it. We leak-trace electronically and under nitrogen, repair the joint, fit a new drier, pull a deep vacuum and weigh in the exact plated charge.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.