Daikin Heat Pump Preventative Servicing — Gas Leak Detection & Refill in Kyalami Business Park

Annual service to keep heat pumps efficient: coil clean, descale, sensor test and charge verification. In Kyalami Business Park this is corporate & commercial work on all heat pumps systems, attended within about 80 minutes of dispatch.

On Daikin equipment specifically — inverter splits, vrv multi-storey systems and ducted plant — the faults we see most in Kyalami Business Park are outdoor pcb failure after surge events and eev coil sticking on multi-splits.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Park management sign-in and asset control. Heat Pump Services bookings in Kyalami Business Park are logged against Block 16 so we can allow for power availability on site.

Typical response window
80 minutes from Midrand & Waterfall Corridor
Distance from Sandton CBD
20.8 km
Municipal water hardness
hard (200 ppm)
Load-shedding schedule
Block 16
Access & compliance
Park management sign-in and asset control.
Typical installed systems
Warehousing, cold storage and industrial chillers.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.

Common questions

Why is my Daikin unit flashing its indicator light in Kyalami Business Park?

A flashing operation lamp means the board has logged a fault code. Pressing the cancel button on the remote and holding it cycles the code out; U0 points to a low charge, U4 to a communication fault between indoor and outdoor units, and A5 to a freeze or high pressure trip.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.