Heat Pump Preventative Servicing — Gas Leak Detection & Refill in Morningside

Annual service to keep heat pumps efficient: coil clean, descale, sensor test and charge verification. In Morningside this is sandton prime work on all heat pumps systems, attended within about 45 minutes of dispatch.

We work across every major brand installed in Morningside, and diagnostics start from the plated design data rather than a guess.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Cluster complexes limit condenser placement to screened plinths. Heat Pump Services bookings in Morningside are logged against Block 4 so we can allow for power availability on site.

Typical response window
45 minutes from Sandton
Distance from Sandton CBD
3 km
Municipal water hardness
moderate (145 ppm)
Load-shedding schedule
Block 4
Access & compliance
Cluster complexes limit condenser placement to screened plinths.
Typical installed systems
Cluster and townhouse dominant, midwall splits with a growing heat pump geyser retrofit rate.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.

Common questions

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Related jobs nearby

Request a callout or quote