Heat Pump Preventative Servicing — Compressor Replacement in Dunkeld

Annual service to keep heat pumps efficient: coil clean, descale, sensor test and charge verification. In Dunkeld this is sandton prime work on all heat pumps systems, attended within about 50 minutes of dispatch.

We work across every major brand installed in Dunkeld, and diagnostics start from the plated design data rather than a guess.

Compressor swaps are done with a full system flush, new drier and an oil-charge check so the replacement is not killed by the original contamination.

Heritage overlays on some streets restrict visible external plant. Heat Pump Services bookings in Dunkeld are logged against Block 6 so we can allow for power availability on site.

Typical response window
50 minutes from Sandton
Distance from Sandton CBD
4.6 km
Municipal water hardness
moderate (130 ppm)
Load-shedding schedule
Block 6
Access & compliance
Heritage overlays on some streets restrict visible external plant.
Typical installed systems
Older character homes retrofitted with concealed multi-split systems.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.

Common questions

Is a compressor replacement guaranteed?

Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.