Aircon Re-Gassing & Leak Repair — no ice being produced in Waterfall Country Estate

Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Waterfall Country Estate this is corporate & commercial work on all split types systems, attended within about 60 minutes of dispatch.

We work across every major brand installed in Waterfall Country Estate, and diagnostics start from the plated design data rather than a guess.

When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.

Strict HOA: screened condensers, approved bracket types and weekday-only works. Aircon Repairs & Servicing bookings in Waterfall Country Estate are logged against Block 15 so we can allow for power availability on site.

Typical response window
60 minutes from Midrand & Waterfall Corridor
Distance from Sandton CBD
14.3 km
Municipal water hardness
hard (180 ppm)
Load-shedding schedule
Block 15
Access & compliance
Strict HOA: screened condensers, approved bracket types and weekday-only works.
Typical installed systems
Large estate homes on ducted and multi-split plant.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

How often should an aircon need re-gassing?

A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.