Daikin Midwall Split Servicing — Gas Leak Detection & Refill in Vorna Valley

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Vorna Valley this is corporate & commercial work on midwall split systems, attended within about 75 minutes of dispatch.

On Daikin equipment specifically — inverter splits, vrv multi-storey systems and ducted plant — the faults we see most in Vorna Valley are outdoor pcb failure after surge events and eev coil sticking on multi-splits.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Complex intercom access. Aircon Repairs & Servicing bookings in Vorna Valley are logged against Block 15 so we can allow for power availability on site.

Typical response window
75 minutes from Midrand & Waterfall Corridor
Distance from Sandton CBD
18.9 km
Municipal water hardness
hard (195 ppm)
Load-shedding schedule
Block 15
Access & compliance
Complex intercom access.
Typical installed systems
Townhouses with midwall splits and heat pump geysers.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Why is my Daikin unit flashing its indicator light in Vorna Valley?

A flashing operation lamp means the board has logged a fault code. Pressing the cancel button on the remote and holding it cycles the code out; U0 points to a low charge, U4 to a communication fault between indoor and outdoor units, and A5 to a freeze or high pressure trip.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.