Commercial HVAC Servicing — Gas Leak Detection & Refill in Halfway House

Scheduled maintenance contracts for office park, retail and boardroom air conditioning plant. In Halfway House this is corporate & commercial work on central hvac systems, attended within about 70 minutes of dispatch.

We work across every major brand installed in Halfway House, and diagnostics start from the plated design data rather than a guess.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Business park reception sign-in. Aircon Repairs & Servicing bookings in Halfway House are logged against Block 15 so we can allow for power availability on site.

Typical response window
70 minutes from Midrand & Waterfall Corridor
Distance from Sandton CBD
17.6 km
Municipal water hardness
hard (190 ppm)
Load-shedding schedule
Block 15
Access & compliance
Business park reception sign-in.
Typical installed systems
Offices, warehouses and cold storage.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R134aHFC (A1)80-140 kPa at -5 degrees C evaporating900-1 200 kPa at 45 degrees C ambientWine cellars, display cabinets, medium-temperature commercial refrigeration and some heat pumps.

Common questions

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.