Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Melrose Arch this is sandton prime work on midwall split systems, attended within about 40 minutes of dispatch.On Midea equipment specifically — value inverter splits, cassettes and hot water heat pumps — the faults we see most in Melrose Arch are outdoor fan capacitor failure and controller communication faults.Every visit starts with a full diagnostic and a written quote before any part is fitted.Precinct management controls contractor access and lift bookings. Aircon Repairs & Servicing bookings in Melrose Arch are logged against Block 6 so we can allow for power availability on site.

Typical response window
40 minutes from Sandton
Distance from Sandton CBD
4.9 km
Municipal water hardness
moderate (135 ppm)
Load-shedding schedule
Block 6
Access & compliance
Precinct management controls contractor access and lift bookings.
Typical installed systems
High-density mixed use: VRV/VRF, restaurant refrigeration and coldrooms.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

My Midea unit heats but will not cool. What is wrong in Melrose Arch?

That points to the four-way reversing valve sticking or its solenoid coil failing. It can often be freed and the coil replaced without opening the sealed system.

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

What does an annual service contract include?

Scheduled visits, priority response between visits, a written condition report per unit and fixed labour rates for the contract year.

Is a compressor replacement guaranteed?

Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.