Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Illovo this is sandton prime work on all split types systems, attended within about 45 minutes of dispatch.On Carrier equipment specifically — ducted central systems, rooftop packaged units and chillers — the faults we see most in Illovo are belt and bearing wear on ahus and rooftop unit economiser damper failure.Every visit starts with a full diagnostic and a written quote before any part is fitted.Mixed residential and office; after-hours access needs building management. Aircon Repairs & Servicing bookings in Illovo are logged against Block 6 so we can allow for power availability on site.

Typical response window
45 minutes from Sandton
Distance from Sandton CBD
4.2 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 6
Access & compliance
Mixed residential and office; after-hours access needs building management.
Typical installed systems
Townhouses and boutique office conversions with light commercial HVAC.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

How often should an aircon need re-gassing?

A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

What does an annual service contract include?

Scheduled visits, priority response between visits, a written condition report per unit and fixed labour rates for the contract year.