Midwall Split Servicing — Gas Leak Detection & Refill in Gallo Manor

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Gallo Manor this is sandton prime work on midwall split systems, attended within about 55 minutes of dispatch.

We work across every major brand installed in Gallo Manor, and diagnostics start from the plated design data rather than a guess.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Standard suburb access with several boomed roads. Aircon Repairs & Servicing bookings in Gallo Manor are logged against Block 9 so we can allow for power availability on site.

Typical response window
55 minutes from Sandton
Distance from Sandton CBD
6.1 km
Municipal water hardness
moderate (150 ppm)
Load-shedding schedule
Block 9
Access & compliance
Standard suburb access with several boomed roads.
Typical installed systems
Family homes and clusters, ducted retrofits increasingly common.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.