Samsung Midwall Split Servicing — Gas Leak Detection & Refill in Atholl

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Atholl this is sandton prime work on midwall split systems, attended within about 45 minutes of dispatch.

On Samsung equipment specifically — wind-free splits, dvm s vrf and side-by-side refrigeration — the faults we see most in Atholl are ice build-up on evaporator in french-door fridges and indoor display board comms loss.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Boomed-off roads with 24/7 guarding. Aircon Repairs & Servicing bookings in Atholl are logged against Block 4 so we can allow for power availability on site.

Typical response window
45 minutes from Sandton
Distance from Sandton CBD
2.8 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 4
Access & compliance
Boomed-off roads with 24/7 guarding.
Typical installed systems
Large homes with ducted plant and secondary staff-quarter units.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

What does an E1 or E4 error mean on a Samsung aircon in Atholl?

E1 is a room temperature sensor error and E4 is an evaporator sensor error. Both are usually a failed thermistor or a connector that has corroded on the indoor board, and both are inexpensive parts once the correct one is identified.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Related jobs nearby

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.