Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Atholl this is sandton prime work on midwall split systems, attended within about 45 minutes of dispatch.We work across every major brand installed in Atholl, and diagnostics start from the plated design data rather than a guess.Condensate leaks traced to blocked drains, failed pumps, poor falls or icing before any panel is refitted.Boomed-off roads with 24/7 guarding. Aircon Repairs & Servicing bookings in Atholl are logged against Block 4 so we can allow for power availability on site.
- Typical response window
- 45 minutes from Sandton
- Distance from Sandton CBD
- 2.8 km
- Municipal water hardness
- moderate (140 ppm)
- Load-shedding schedule
- Block 4
- Access & compliance
- Boomed-off roads with 24/7 guarding.
- Typical installed systems
- Large homes with ducted plant and secondary staff-quarter units.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Do you top up gas without finding the leak?
No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.
What does an annual service contract include?
Scheduled visits, priority response between visits, a written condition report per unit and fixed labour rates for the contract year.
Is a compressor replacement guaranteed?
Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.