Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Atholl this is sandton prime work on midwall split systems, attended within about 45 minutes of dispatch.On Daikin equipment specifically — inverter splits, vrv multi-storey systems and ducted plant — the faults we see most in Atholl are refrigerant loss at flare joints and outdoor pcb failure after surge events.Every visit starts with a full diagnostic and a written quote before any part is fitted.Boomed-off roads with 24/7 guarding. Aircon Repairs & Servicing bookings in Atholl are logged against Block 4 so we can allow for power availability on site.

Typical response window
45 minutes from Sandton
Distance from Sandton CBD
2.8 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 4
Access & compliance
Boomed-off roads with 24/7 guarding.
Typical installed systems
Large homes with ducted plant and secondary staff-quarter units.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Why is my Daikin unit flashing its indicator light in Atholl?

A flashing operation lamp means the board has logged a fault code. Pressing the cancel button on the remote and holding it cycles the code out; U0 points to a low charge, U4 to a communication fault between indoor and outdoor units, and A5 to a freeze or high pressure trip.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.