Aircon Re-Gassing & Leak Repair — Preventative Service in Atholl Square
Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Atholl Square this is sandton prime work on all split types systems, attended within about 40 minutes of dispatch.
We work across every major brand installed in Atholl Square, and diagnostics start from the plated design data rather than a guess.
A scheduled service that keeps efficiency, warranty cover and indoor air quality intact, with a written condition report.
Tenant coordination for shared plant. Aircon Repairs & Servicing bookings in Atholl Square are logged against Block 4 so we can allow for power availability on site.
- Typical response window
- 40 minutes from Sandton
- Distance from Sandton CBD
- 3.1 km
- Municipal water hardness
- moderate (140 ppm)
- Load-shedding schedule
- Block 4
- Access & compliance
- Tenant coordination for shared plant.
- Typical installed systems
- Restaurant and deli refrigeration with split HVAC.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
How often should an aircon need re-gassing?
A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.
Can you work after trading hours?
Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.
Is scale really a problem for ice machines here?
Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.
There is water on the floor under my ice machine, can you find the leak?
We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.
Related jobs nearby
- Inverter Aircon Repair in Atholl Square
- LG Inverter Aircon Repair
- Alliance Inverter Aircon Repair
- Midea Inverter Aircon Repair
- Inverter Aircon Repair — Annual Service Contract
- Inverter Aircon Repair — Thermostat & Controller Replacement
- Inverter Aircon Repair — Supply & Installation
- Midwall Split Servicing in Atholl Square
- Dunham-Bush Midwall Split Servicing
- Daikin Midwall Split Servicing
- Samsung Midwall Split Servicing
- Midwall Split Servicing — water leaking from the machine
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.