Aircon Re-Gassing & Leak Repair — no ice being produced in Saxonwold

Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Saxonwold this is upper residential work on all split types systems, attended within about 50 minutes of dispatch.

We work across every major brand installed in Saxonwold, and diagnostics start from the plated design data rather than a guess.

When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.

Heritage-sensitive suburb; visible plant often restricted. Aircon Repairs & Servicing bookings in Saxonwold are logged against Block 6 so we can allow for power availability on site.

Typical response window
50 minutes from Rosebank & Parks Belt
Distance from Sandton CBD
7.6 km
Municipal water hardness
moderate (130 ppm)
Load-shedding schedule
Block 6
Access & compliance
Heritage-sensitive suburb; visible plant often restricted.
Typical installed systems
Large heritage homes with concealed ducted and multi-split retrofits.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

How often should an aircon need re-gassing?

A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.