Aircon Re-Gassing & Leak Repair — Error Code Diagnosis & Repair in Norwood

Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Norwood this is upper residential work on all split types systems, attended within about 55 minutes of dispatch.

We work across every major brand installed in Norwood, and diagnostics start from the plated design data rather than a guess.

Codes are read from the board rather than guessed at, then traced to the actual sensor, valve or drive fault behind them.

Restaurant strip requires after-hours work. Aircon Repairs & Servicing bookings in Norwood are logged against Block 8 so we can allow for power availability on site.

Typical response window
55 minutes from Rosebank & Parks Belt
Distance from Sandton CBD
10.9 km
Municipal water hardness
moderate (140 ppm)
Load-shedding schedule
Block 8
Access & compliance
Restaurant strip requires after-hours work.
Typical installed systems
Homes plus a dense restaurant refrigeration cluster.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

How often should an aircon need re-gassing?

A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

My ice machine runs but makes no ice, is it worth repairing?

Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.

Why is my ice cloudy or melting too fast?

Cloudy, soft ice means the freeze cycle is being cut short or the water is carrying too many dissolved solids. We test hardness and TDS on site, fit the right filtration, descale the plate and re-time the cycle so cubes freeze clear and hard.