Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Killarney this is upper residential work on midwall split systems, attended within about 50 minutes of dispatch.We work across every major brand installed in Killarney, and diagnostics start from the plated design data rather than a guess.A scheduled service that keeps efficiency, warranty cover and indoor air quality intact, with a written condition report.Apartment building managers control roof and riser access. Aircon Repairs & Servicing bookings in Killarney are logged against Block 7 so we can allow for power availability on site.

Typical response window
50 minutes from Rosebank & Parks Belt
Distance from Sandton CBD
8 km
Municipal water hardness
moderate (135 ppm)
Load-shedding schedule
Block 7
Access & compliance
Apartment building managers control roof and riser access.
Typical installed systems
High-rise apartments and retail on central and packaged plant.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Can you work after trading hours?

Yes. Retail, restaurant and office work is routinely scheduled at night or early morning under a permit-to-work so trading is not interrupted.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.