Ducted Central HVAC Repair — no ice being produced in Craighall
Repairs to ducted central plant: fan coils, dampers, ducting leaks, thermostats and condensing units. In Craighall this is upper residential work on ducted central systems, attended within about 50 minutes of dispatch.
We work across every major brand installed in Craighall, and diagnostics start from the plated design data rather than a guess.
When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.
Suburb watch entry logging. Aircon Repairs & Servicing bookings in Craighall are logged against Block 6 so we can allow for power availability on site.
- Typical response window
- 50 minutes from Rosebank & Parks Belt
- Distance from Sandton CBD
- 6.9 km
- Municipal water hardness
- moderate (135 ppm)
- Load-shedding schedule
- Block 6
- Access & compliance
- Suburb watch entry logging.
- Typical installed systems
- Family homes with mixed-age split systems.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
Common questions
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Do you top up gas without finding the leak?
No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.
What does an annual service contract include?
Scheduled visits, priority response between visits, a written condition report per unit and fixed labour rates for the contract year.
Related jobs nearby
- Inverter Aircon Repair in Craighall
- Carrier Inverter Aircon Repair
- York Inverter Aircon Repair
- Dunham-Bush Inverter Aircon Repair
- Inverter Aircon Repair — Water Leak Repair
- Inverter Aircon Repair — no ice being produced
- Inverter Aircon Repair — cloudy, soft or hollow ice
- Midwall Split Servicing in Craighall
- Carrier Midwall Split Servicing
- York Midwall Split Servicing
- Dunham-Bush Midwall Split Servicing
- Midwall Split Servicing — Error Code Diagnosis & Repair
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.