Aircon Re-Gassing & Leak Repair — scale build-up and descaling in Craighall
Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Craighall this is upper residential work on all split types systems, attended within about 50 minutes of dispatch.
We work across every major brand installed in Craighall, and diagnostics start from the plated design data rather than a guess.
Hard water in this part of Johannesburg lays scale on evaporator plates, distribution tubes and sumps within months. We strip, descale with food-safe acid, sanitise, and re-test output, then leave a hygiene record you can show an inspector.
Suburb watch entry logging. Aircon Repairs & Servicing bookings in Craighall are logged against Block 6 so we can allow for power availability on site.
- Typical response window
- 50 minutes from Rosebank & Parks Belt
- Distance from Sandton CBD
- 6.9 km
- Municipal water hardness
- moderate (135 ppm)
- Load-shedding schedule
- Block 6
- Access & compliance
- Suburb watch entry logging.
- Typical installed systems
- Family homes with mixed-age split systems.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
How often should an aircon need re-gassing?
A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.
Is scale really a problem for ice machines here?
Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Related jobs nearby
- Inverter Aircon Repair in Craighall
- Carrier Inverter Aircon Repair
- York Inverter Aircon Repair
- Dunham-Bush Inverter Aircon Repair
- Inverter Aircon Repair — Water Leak Repair
- Inverter Aircon Repair — no ice being produced
- Inverter Aircon Repair — cloudy, soft or hollow ice
- Midwall Split Servicing in Craighall
- Carrier Midwall Split Servicing
- York Midwall Split Servicing
- Dunham-Bush Midwall Split Servicing
- Midwall Split Servicing — Error Code Diagnosis & Repair
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.