Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Witkoppen this is luxury gated estates work on midwall split systems, attended within about 65 minutes of dispatch.We work across every major brand installed in Witkoppen, and diagnostics start from the plated design data rather than a guess.Compressor swaps are done with a full system flush, new drier and an oil-charge check so the replacement is not killed by the original contamination.Mixed access; some sections open, some boomed. Aircon Repairs & Servicing bookings in Witkoppen are logged against Block 12 so we can allow for power availability on site.

Typical response window
65 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
13.6 km
Municipal water hardness
hard (190 ppm)
Load-shedding schedule
Block 12
Access & compliance
Mixed access; some sections open, some boomed.
Typical installed systems
Family homes and small commercial premises.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Is a compressor replacement guaranteed?

Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.