Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Steyn City this is luxury gated estates work on midwall split systems, attended within about 75 minutes of dispatch.We work across every major brand installed in Steyn City, and diagnostics start from the plated design data rather than a guess.Compressor swaps are done with a full system flush, new drier and an oil-charge check so the replacement is not killed by the original contamination.Estate induction, biometric registration and escorted access for contractors. Aircon Repairs & Servicing bookings in Steyn City are logged against Block 13 so we can allow for power availability on site.

Typical response window
75 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
19.2 km
Municipal water hardness
hard (210 ppm)
Load-shedding schedule
Block 13
Access & compliance
Estate induction, biometric registration and escorted access for contractors.
Typical installed systems
Ultra-prime homes with full-home VRV, wine rooms and multiple heat pumps.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Is a compressor replacement guaranteed?

Yes. Replacements are done with a system flush and new drier, and both part and workmanship are warranted, provided the original cause of failure is corrected.

Do you work inside gated estates?

Regularly. Technician details, ID numbers and vehicle registration are submitted to the HOA or gatehouse before the appointment so access is cleared in advance.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.