Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Lonehill this is luxury gated estates work on midwall split systems, attended within about 65 minutes of dispatch.We work across every major brand installed in Lonehill, and diagnostics start from the plated design data rather than a guess.Hard water in this part of Johannesburg lays scale on evaporator plates, distribution tubes and sumps within months. We strip, descale with food-safe acid, sanitise, and re-test output, then leave a hygiene record you can show an inspector.Most complexes are boomed with visitor biometrics. Aircon Repairs & Servicing bookings in Lonehill are logged against Block 12 so we can allow for power availability on site.

Typical response window
65 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
14.1 km
Municipal water hardness
hard (185 ppm)
Load-shedding schedule
Block 12
Access & compliance
Most complexes are boomed with visitor biometrics.
Typical installed systems
Clusters and family homes with multi-split systems.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Is scale really a problem for ice machines here?

Yes, it is the single biggest cause of lost output on this water supply. Scale insulates the evaporator, so the machine runs longer for less ice and eventually pits the plate. Regular descaling is far cheaper than an evaporator replacement.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.

Request a callout or quote

Send it straight to our WhatsApp for the fastest response, or call 069 268 0988 / email info@reyds.co.za.