Aircon Re-Gassing & Leak Repair — no ice being produced in Lonehill
Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Lonehill this is luxury gated estates work on all split types systems, attended within about 65 minutes of dispatch.
We work across every major brand installed in Lonehill, and diagnostics start from the plated design data rather than a guess.
When a machine runs but drops no ice, the fault is almost always one of four things: water supply or inlet valve, a failed water pump, a blocked or scaled evaporator plate, or a harvest cycle that never completes. We test each in that order and confirm output against the plated kg-per-24-hour figure before we leave.
Most complexes are boomed with visitor biometrics. Aircon Repairs & Servicing bookings in Lonehill are logged against Block 12 so we can allow for power availability on site.
- Typical response window
- 65 minutes from Fourways & Northern Suburbs
- Distance from Sandton CBD
- 14.1 km
- Municipal water hardness
- hard (185 ppm)
- Load-shedding schedule
- Block 12
- Access & compliance
- Most complexes are boomed with visitor biometrics.
- Typical installed systems
- Clusters and family homes with multi-split systems.
Refrigerant data
| Gas | Classification | Suction pressure | Discharge pressure | Typical use |
|---|---|---|---|---|
| R410a | HFC blend (A1) | 280-320 kPa at 7 degrees C evaporating | 2 600-3 000 kPa at 45 degrees C ambient | Most inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005. |
| R32 | HFC (A2L, mildly flammable) | 300-340 kPa at 7 degrees C evaporating | 2 700-3 100 kPa at 45 degrees C ambient | Current-generation inverter splits and heat pumps. |
| R22 | HCFC (phased out) | 480-520 kPa at 7 degrees C evaporating | 1 700-2 000 kPa at 45 degrees C ambient | Legacy splits and ducted plant installed before the phase-out. |
Common questions
How often should an aircon need re-gassing?
A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.
My ice machine runs but makes no ice, is it worth repairing?
Usually yes. The four common causes (water inlet valve, water pump, scaled evaporator and a stalled harvest cycle) are all repairable at a fraction of replacement cost. We quote in writing after the diagnostic and tell you honestly when a machine is past economic repair.
Do you charge a callout fee?
A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.
Related jobs nearby
- Inverter Aircon Repair in Lonehill
- Midea Inverter Aircon Repair
- Sirair Inverter Aircon Repair
- Carrier Inverter Aircon Repair
- Inverter Aircon Repair — Preventative Service
- Inverter Aircon Repair — Annual Service Contract
- Inverter Aircon Repair — Thermostat & Controller Replacement
- Midwall Split Servicing in Lonehill
- Alliance Midwall Split Servicing
- Midea Midwall Split Servicing
- Sirair Midwall Split Servicing
- Midwall Split Servicing — slow or stalled harvest cycle
Request a callout or quote
Send it straight to our WhatsApp for the fastest response, or call 012 546 6670 / email info@reyds.co.za.