Aircon Re-Gassing & Leak Repair — water leaking from the machine in Kengies

Pressure testing, leak detection, vacuum and accurate weighed re-gas of R410a, R32 and legacy R22 systems. In Kengies this is luxury gated estates work on all split types systems, attended within about 65 minutes of dispatch.

We work across every major brand installed in Kengies, and diagnostics start from the plated design data rather than a guess.

Water on the floor around an ice machine is usually the inlet valve, a split distribution tube, a blocked drain, or a bin drain that has backed up. We trace the leak wet, not by guesswork, and pressure-test the water side before recommissioning.

Complex intercom access. Aircon Repairs & Servicing bookings in Kengies are logged against Block 12 so we can allow for power availability on site.

Typical response window
65 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
14.8 km
Municipal water hardness
hard (190 ppm)
Load-shedding schedule
Block 12
Access & compliance
Complex intercom access.
Typical installed systems
Townhouse complexes with midwall splits.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

How often should an aircon need re-gassing?

A correctly installed system should never need gas. If it does, there is a leak, so we pressure test and repair the leak before charging rather than topping up annually.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.