Daikin Midwall Split Servicing — Gas Leak Detection & Refill in Jukskei Park

Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Jukskei Park this is luxury gated estates work on midwall split systems, attended within about 65 minutes of dispatch.

On Daikin equipment specifically — inverter splits, vrv multi-storey systems and ducted plant — the faults we see most in Jukskei Park are refrigerant loss at flare joints and outdoor pcb failure after surge events.

Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.

Suburb watch entry logging. Aircon Repairs & Servicing bookings in Jukskei Park are logged against Block 12 so we can allow for power availability on site.

Typical response window
65 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
13.9 km
Municipal water hardness
hard (190 ppm)
Load-shedding schedule
Block 12
Access & compliance
Suburb watch entry logging.
Typical installed systems
Family homes with midwall splits.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Why is my Daikin unit flashing its indicator light in Jukskei Park?

A flashing operation lamp means the board has logged a fault code. Pressing the cancel button on the remote and holding it cycles the code out; U0 points to a low charge, U4 to a communication fault between indoor and outdoor units, and A5 to a freeze or high pressure trip.

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you charge a callout fee?

A standard callout and diagnostic fee applies and is quoted upfront. It is credited against the repair when you accept the quote.