Full preventative service: coil clean, filter replacement, drain flush, gas pressure check and electrical torque test. In Cedar Lakes this is luxury gated estates work on midwall split systems, attended within about 70 minutes of dispatch.We work across every major brand installed in Cedar Lakes, and diagnostics start from the plated design data rather than a guess.Leaks are found before gas goes in: nitrogen pressure test, electronic sniffer and UV dye, then a triple evacuation and a weighed charge.Gated estate; HOA approval required for external unit brackets. Aircon Repairs & Servicing bookings in Cedar Lakes are logged against Block 13 so we can allow for power availability on site.

Typical response window
70 minutes from Fourways & Northern Suburbs
Distance from Sandton CBD
15.8 km
Municipal water hardness
hard (195 ppm)
Load-shedding schedule
Block 13
Access & compliance
Gated estate; HOA approval required for external unit brackets.
Typical installed systems
Estate homes with multi-split and pool heat pumps.

Refrigerant data

GasClassificationSuction pressureDischarge pressureTypical use
R410aHFC blend (A1)280-320 kPa at 7 degrees C evaporating2 600-3 000 kPa at 45 degrees C ambientMost inverter splits, ducted systems, VRV/VRF and heat pumps installed since 2005.
R32HFC (A2L, mildly flammable)300-340 kPa at 7 degrees C evaporating2 700-3 100 kPa at 45 degrees C ambientCurrent-generation inverter splits and heat pumps.
R22HCFC (phased out)480-520 kPa at 7 degrees C evaporating1 700-2 000 kPa at 45 degrees C ambientLegacy splits and ducted plant installed before the phase-out.

Common questions

Do you top up gas without finding the leak?

No. A weighed charge into a leaking system is money out the window, so the leak is found and repaired first, then the system is evacuated and charged to the plated weight.

Do you work inside gated estates?

Regularly. Technician details, ID numbers and vehicle registration are submitted to the HOA or gatehouse before the appointment so access is cleared in advance.

There is water on the floor under my ice machine, can you find the leak?

We trace it wet rather than guessing: inlet valve weep, split distribution tube, blocked machine drain or a backed-up bin drain all present the same way. The water side is pressure-tested before we recommission.

How urgent is a slow harvest cycle?

Treat it as urgent. A stalling harvest leaves the plate frozen solid, output collapses and the compressor runs against high head pressure, which is how a cheap solenoid fault turns into a compressor replacement.